SONOLINE G50 Ultrasound System


GENERAL INFORMATION

The SONOLINE G50 ultrasound system is a complete, portable imaging platform that offers advanced all-digital ultrasound technologies in a customizable solution - a solution designed to meet your individual clinical and economic needs.

The G50 system provides exceptional image quality and superb workflow solutions to address a wide variety of specialty and general applications.

In addition, the G50 system provides a high level of standard features such as tissue harmonic imaging (THI) and directional Power Doppler.

SYSTEM ARCHITECTURE

The new generation all-digital technology of the G50 system preserves signal integrity of ultrasound information throughout the entire signal path from transducer to display.

The open architecture is ready to seamlessly integrate innovative features such as the optional DIMAQ-IP integrated workstation, SieScape panoramic imaging, 3-Scape real-time 3D imaging and additional functionality such as cardiac imaging and stress echo.

User Interface

  User-centric control panel with homebase layout

  Windows® based operating principles and on-screen
icons to activate most frequently used functions

  Adjustable control panel back-lit illumination

  Function key active state brightening

  Digital Liquid Crystal Display (LCD) provides easy and
immediate access to secondary imaging controls

  Wrist support to help reduce operator repetitive
stress disorders

  Retractable alphanumeric keyboard with overhead
illumination for standard text, function keys and system
programming

  Up to 32 QuickSet user programmable system parameters
for individual transducer/application settings. QuickSet
parameters combine all preferred imaging mode parameters,
annotation text and measurements into one user preset

  Configurable two-pedal footswitch

Language Support

  Image screen, control panel overlay and operating
instructions all available in English, German, French,
Spanish and Italian

Monitor

  MultiSync, 15-inch, high resolution, progressive scan
(non-interlaced)

  800 x 600 pixel display matrix with a recordable image area
of 800 x 600 pixels (SVGA)

  Monitor tilt of 10 degrees up, 8.5 degrees down and swivel
of 180 degrees

  Digital on-screen display brightness and contrast controls
with factory default presets

  Energy Savings Compliant per VESA Display Power
Management Signaling standard

MO Drive

  Removable, standard 3.5-inch 640 MB magneto-optical disk

  Allows storage of patient images, reports, and patient ID list,
back-up for user and system presets

  Supports system software updates and upgrades

Hard Drive (with DIMAQ-IP option only)

  Internal 40 GB Hard Drive for patient database management

  Allows storage of complete patient studies including images,
dynamic clips, reports and measurements

  Image storage capacity up to 42,000 images; color or
black/white, or storage of approximately 6,300 dynamic clips

CD-RW Drive (with DIMAQ-IP option only)

  Removable 650 MB read/write CD-R

  Allows storage and archiving of patient studies that include
images, dynamic clips, reports and measurements

  Storage capacity dependent upon patient study size

  Export of images in TIF and clips in AVI file format

Audio Speakers

  High performance audio speakers integrated in the monitor

Transducer Ports

  Two universal array transducer ports that support Curved
Array, Linear Array and Phased Array*

*requires cardiac imaging option)

  Optional additional array transducer port

  Optional sector transducer port

  Electronic transducer selection

  Industrial design provides easy access to all transducer ports

Transducer Storage

  Four configurable transducer holders to support all
transducer designs

  Two holders for gel bottle storage

  Ergonomic cable management and secure cable management
during exams and transport

  Unique transducer holder for endocavity transducers for easy
access and storage

Acoustic Output Management

  On-screen acoustic power indicator (AIUM/NEMA output
display standard)

Physiological Interface (with cardiac imaging option only)

  Standard 3-lead ECG interface

  Continuous display in all real time modes

  R-Wave Single and Dual Trigger function

  Heart Rate display

  Adjustable gain and trace position on screen

  Selection for external ECG input

 

 

 

 

 

 

 

 

 

OPERATING/DISPLAY MODES

   2D imaging in fundamental and harmonic modes

   Tissue and color M-mode

   B/W SieScape panoramic imaging (option)

   3-Scape real-time 3D imaging (option)

   Color Doppler Velocity mode

   Power Doppler mode

   Directional Power Doppler mode

   PW Pulsed Wave spectral Doppler mode

   Steerable Continuous Wave spectral Doppler mode (with
cardiac imaging option only)

   Duplex mode

   Triplex mode

   ECG trace in all modes (with cardiac imaging option only)

   Flexible combination of imaging modes in side-by-side Dual
and Dual Select in real-time, and digital cine replay

   Selectable split screen display formats in 2D/color with
M-mode and/or spectral Doppler mode: top-bottom or
side-by-side in real-time and digital cine replay

Beamforming in 2D Imaging

   New generation all-digital beam former technology

   Patented ASIC technology preserves signal integrity through
precision up-sampling for better beam definition

   2D-mode line density up to 322 lines

   Up to 256 processing channels

   Total system dynamic range of > 1 54 dB

Focusing

   Up to four transmit focal zones

   Digital dynamic receive focusing with dynamic apodization

2D Image Processing

   MultiHertz multiple-frequency imaging with up to five
user-selectable transmit frequencies

   Res/Speed selection for Std (Standard) and Dtl (Detail)

   5 Persistence levels: off, 1-4

   4 Edge enhancement levels: off, 1-3

   Display dynamic range: 35 to 70 dB in one-decibel
increments

   Adjustable gain from 0 to 40 dB in one-decibel increments,
and total of 60 dB including DGC

   8 DGC controls for Depth Gain Compensation

   6 user-selectable gray maps

   4 user-selectable 2D colorization maps (Sepia, Mag,
Temp, Bow)

2D Image Display

   Full screen, Split and Dual Select screen formats

   L/R for all formats in real-time and digital cine replay

   90 degree rotation of image for all array transducers

   Image Depth from 2 to 24 cm in 1.0 cm increments

-  transducer dependent

   Sector: selectable field of view from 28 to 90 degrees

   Digital read/write zoom with image pan

 

-   Available on live and cine replay images

-   Up to 20 X zoom transducer dependent

2D Calipers - Generic Measurements and Calculations

   Multiple cursor sets on frozen and cine playback images

   Up to eight distance measurements per screen

  Distance, depth from skin line

  Trace Length measurement

  Angle measurement

  Area and circumference: ellipse, trace, cross, spline

  Compound Measurements:

 

-   Volume: user-selectable calculated by 2-Plane 3 distances,
2-Plane ellipse, 2-Plane trace, 1 -Plane 2 distances, 1 -Plane
ellipse or 1 -Plane disk measurements

-   Flow volume: Combined velocity and distance, or velocity
and ellipse measurements

-   Stenosis: user-selectable, calculated by area, or diameter
measurements

Tissue Harmonic Imaging

Tissue Harmonic Imaging with selectable frequencies increases success with difficult-to-image patients, improving diagnostic confidence. Dramatically improves contrast and spatial resolution by reducing noise and clutter in the image.

  MultiHertz multiple-frequency imaging capability in Tissue
Harmonic Imaging (THI)

  Available on the C5-2 and C6-3 3D curved array and P4-2*
phased array transducers (*requires cardiac imaging option)

PW Pulsed Wave spectral Doppler

  Available on all imaging array transducers

  Up to two user-selectable transmit frequencies per
transducer, frequency range is 2.1 to 7.0 MHz

  4 sweep speed selections: 2, 4, 8, 16 sec.

  4 selectable pre-processing curves

  8 selectable post processing gray maps

  4 user-selectable Doppler colorization maps (Sepia,
Mag, Temp, Bow)

  Adjustable gain from 30 to 60 dB in one-decibel increments

  PRF range: 1,400 to 1 5,300 Hz

  Velocity scale range: ±14.7 cm/sec to ±277. 4 cm/sec
(with High PRF) at 0° angle correction

  Angle correction 0 - 90° in one-degree increments

  Auto angle correction 60/0/60° for vascular applications

  Gate size: from 0.4 up to 1 5.1 mm

  7 wall filter selections, range 22 to 2,028 Hz proportional
to PRF - transducer dependent

  9 levels of baseline shift

  Spectral invert

  Auto-Doppler trace function with auto-calculation and
display of PS, MD, TAVmax, PI, RI and S/D

CW Continuous Wave spectral Doppler (requires cardiac imaging option)

  Steerable CW available on phased array transducers

  Up to two user-selectable transmit frequencies per transducer

  4 sweep speed selections: 2, 4, 8, 1 6 sec.

  4 selectable pre-processing curves

  8 selectable post processing gray maps

  4 user-selectable Doppler colorization maps (Sepia, Mag,
Temp, Bow)

  Adjustable gain from 30 to 60 dB in one-decibel increments

  PRF scale range: 4.0 to 47.6 kHz

  Velocity range: ±0.7 m/sec to ±8.5 m/sec

  7 wall filter selections, range 68 to 6,333 Hz -
proportional to PRF - transducer dependent

  Nine levels of baseline shift

  Spectral invert

Spectral Doppler Display

  Full screen D trace, 2D/Doppler mode, triplex or update
2D/C/Doppler, 2D/C/Doppler/M-mode

  Three imaging display formats

-  top-bottom: 1/3-2/3, 1/2-1/2; side-by-side: 40-60

Doppler Calipers - Generic Measurements and Calculations

  Multiple cursor sets on frozen and cine playback images

  Velocity/Frequency/Pressure Gradient

  Heart rate/Heart cycle/Time

  Auto-Trace measurements and calculations including
PS, MD, TAVmax, PI, RI and S/D or VTI (cardiac)

  Resistive Index (RI)

  Pulsatility Index (PI), including Peak-to-Peak method

  Time Average Velocity max (TAV)

  Systolic/diastolic ratio (S/D)

  Velocity Time Integral (VTI)

  Acceleration/Deceleration

  Flow volume using combined velocity and distance, or
velocity and ellipse measurements

  Doppler angle correction after measurement

Color Doppler Velocity Imaging

  Available on all imaging array transducers

  AutoColor technology for single-step optimization of color
Doppler parameters

  Parallel signal processing* (*requires cardiac imaging option)

-  transducer dependent

  Advanced processing in Color mode resulting in excellent
spatial resolution and superior flash suppression

  Left/right steer on all linear array transducers

  Up to two user-selectable transmit frequencies per
transducer, frequency range is 2.1 to 7.0 MHz

  Up to 8 user-selectable color velocity maps (4 velocity;
4 velocity/variance)

  Velocity scale range: 1.2 cm/sec to 183 cm/sec -
transducer dependent

  Adjustable gain from 0 to 30 dB in one-decibel increments

  5 Color line density selections

  4 Motion Cut selections proportional to velocity scale

  10 Noise Cut filter selections (spatial smoothing)

  12 Tissue/color priority selections

  8 Color persistence levels

  5 Flow state selections per exam type for quick adjustment
of color flow depending on pathology

  Color invert

Power Doppler Imaging Directional Power Doppler Imaging

  Available on all imaging array transducers

  Parallel signal processing* (*requires cardiac imaging option) ■
transducer dependent

  Left/right steer on all linear array transducers

  Up to two user-selectable transmit frequencies per
transducer, frequency range is 2.1 to 7.0 MHz

  Selection of 6 Power Doppler maps

  Selection of 4 Directional Power Doppler maps

  PRF scale range: 330 Hz to 12,550 Hz - transducer
dependent

  Gain: 0 to 30 dB in one-decibel increments

  5 Color line density selections

  4 Motion Cut selections proportional to PRF scale

  10 Noise Cut filter selections

  12 Tissue/color priority selections

  8 Color persistence levels

  5 Flash suppression levels

  5 Flow state selections per exam type for quick adjustment
of color flow depending on pathology

Color and Power Doppler Display

  2D/C mode, Split 2D-2D/C mode, Dual Select 2D/C mode

  2D/C/D mode (simultaneous triplex), 2D/C/D mode (update)

  2D/C/M mode simultaneous

M-Mode

  Available on all imaging array transducers

  Up to five user-selectable transmit frequencies,
including fundamental and harmonics

  4 Edge Enhancement selections

  Display dynamic range: 35 to 70 dB in one-decibel increments

  Adjustable gain from 0 to 40 dB in one-decibel increments

  6 user-selectable gray maps

  4 user-selectable M-mode colorization maps (Sepia,
Mag, Temp, Bow)

  4 sweep speed selections: 2, 4, 8, 1 6 sec.

M-Mode Image Display

  Full screen M-mode, 2D/M-mode, 2D/C/M-mode,
2D/Doppler/M-mode, 2D/C/Doppler/M-mode

  Three imaging display formats - top-bottom: 1/3-2/3,
1/2-1/2; side-by-side: 40-60

M-Mode Calipers - Generic Measurements and Calculations

  Multiple cursor sets on frozen and cine playback images

  Distance

  Time

  Ratio

  Heart rate/heart cycle

  Slope

  Compound Measurements: Flow volume: Combined velocity
and distance, or velocity and ellipse measurements

FREEZE, CINE AND CINE POST-PROCESSING FUNCTIONS

Cine Review

Cine feature offers post-acquisition optimization of all real-time post-processing functions.

   Frame-by-frame cine loop review and continuous cine motion
review, including control of playback rate

   Independent cine review in mixed modes (2D/M, 2D/Doppler,
2D/C/Doppler)

   Independent cine review in 2D Dual Select mode with image
align playback feature


 

 

   Standard Cine Memory: providing up to 255 2D-mode
images or up to 255 2D/C images

   Up to 30 seconds Doppler Cine, or up to 30 seconds
M-mode Cine

   Cine Store: Multiple single frame storage with clipboard-
review allowing post processing, measurement and
annotation functions

Post Processing Features in Freeze Frame or Cine

  2D-mode

-    Zoom/pan

-    Gray map

-    2D-mode colorization map

-    Measurements/reports/annotations/pictograms

  Color

-    Zoom/pan

-    Color map

-    Color invert

-    Measurements/reports/annotations/pictograms

  Doppler

-    Gray map

-    Doppler colorization map

-    Angle correct

-    Measurements/reports/annotations/pictograms

  M-mode

-    Gray map

-    M-mode colorization map

-    Measurements/reports/annotations/pictograms

TRANSDUCER TECHNOLOGY

Ultra-sensitive, wideband transducers, matched with user-selectable MultiHertz multiple-frequency imaging, improve penetration and resolution.

Depending on the transducer, the user can select up to five 2D and THI frequencies and two color and spectral Doppler frequencies, expanding the clinical versatility of a single transducer, and thereby maximizing transducer investment.

  Wideband MultiHertz imaging allows user selection of
independent 2D and color frequencies for optimal resolution
and penetration

  microCase transducer miniaturization technology combined
with SuppleFlex transducer cables provide small,
lightweight, comfortable transducers, designed to help
reduce operator fatigue during prolonged scanning sessions

  Universal, stainless steel and disposable biopsy guides for
specified linear and curved array transducers

  Innovative ultra low-loss lens materials and microelectronic
technologies for efficient performance and increased signal
bandwidth

  Frequency range: 2.0 - 13.0 MHz

Note: See dedicated transducer cards for more information.


APPLICATIONS

The SONOLINE G50 ultrasound system is designed to support a wide variety of specialty and general imaging applications. Factory supplied exam and transducer dependent imaging presets have been carefully optimized for each application to provide consistency, reliability, and increased productivity. Selected applications include body markers, text and annotation labels, worksheets and reports.

  Abdominal

  Cardiac

  Vascular (C-Vas, P-Vas, Venous)

  Early Obstetrics

  Obstetrics

  Gynecology

  Small Parts (breast, testicle, thyroid)

  Orthopedics

  Urology (prostate)

  Cranial

  Surgery

EXAM-SPECIFIC MEASUREMENTS AND CALCULATIONS

The measurement function is arranged by exam type and is available for use with all exams types. The ultrasound system has measurement and report packages for the following exam types:

Abdomen

All general measurements and calculations

Surgical

All general measurements and calculations

Breast

All general measurements and calculations

Testicle

All general measurements and calculations

Thyroid

  All general measurements and calculations

  Thyroid volume

Urology

  All general measurements and calculations

  Micturated volume

  Prostate and urology patient report

Cerebrovascular

  All general measurements and calculations

  CCA, ICA1, ICA2, ICA3, ECA, and VA measurements

  Area Percent Stenosis and Diameter Percent Stenosis
measurements

  Cerebrovascular patient report

Peripheral Vascular

  All general measurements and calculations

  Right and left extremity measurements

  Peripheral vascular patient report

 

Venous

  All general measurements and calculations

  Right and left extremity measurements

  Venous patient report

Cranial

All general measurements and calculations

Gynecology

  All general measurements and calculations

  Right and left follicle, uterus, and right and left ovary
measurements

  Gynecology patient report

Obstetrics

  All general measurements and calculations

  Early Obstetrics menstrual age (MA) measurements are MSD,
CRL, ATD, and Yolk Sac

  Menstrual Age Parameter Labels are MSD, CRL, BPD, OFD, HC,
AC, ATD, ASD, FL, HU, UL, TL, FT, and BN

  Up to four user-defined parameter labels and two user-
defined measurement labels are available in 2D-mode

  Calculations include: EFW from the selected reference, HC/AC,
TCD/AC, LVW/HW, CorBPD, FL/AC, FL/BPD, CI, AFI, and Fetal
Heart Rate

  Calculations for both gestational age (GA) and ultrasound
menstrual age, and estimated date of confinement (EDC)

  Early Obstetric patient report and Standard Obstetric patient
report include a worksheet for viewing the progress of the
report during the exam process and to edit the report

  Multiple fetus reporting capabilities

  Growth Analysis Graphs with exam file linking

  OB patient report and worksheet including Fetal Heart
report page

Cardiac

  All general adult measurements and calculations

  Volume formulas for Left Ventricular function assessment in
2D-mode and M-mode

  2D-mode, M-mode, and Doppler calculations

  M-Mode Slope, Heart Rate, Time, and Distance
measurements

  Doppler Acceleration, Deceleration, Trace, Heart Rate, Time
and Velocity measurements

  Cardiac patient report and worksheet for 2D-mode, M-mode,
and Doppler

Orthopedic

  All general measurements and calculations

  Right and Left Hip Angle measurement

  Classification and Graf Sonometer

  Hip angle patient report

OPTIONS

DIMAQ-IP (Option)

Digital patient study storage and archiving The DIMAQ-IP integrated workstation allows for digital acquisition, storage, review and transfer of complete ultrasound studies, including static images and dynamic clips as well as measurements, calculations and reports. Embedded DICOM allows for easy integration of the system into departmental or hospital-wide PACS.

Patient study management

Replay of digitally stored images and clips in a selectable 1 -up, 4-up, 9-up or 16-up screen format. The patient study screen allows for study selection, search, and deletion or for export to CD-R.

  Internal 40 GB hard drive for patient data management

  CD-RW drive for 650 MB read/write CD-R storage media

  Hard drive capacity:

-    approximately 42,000 b/w or color images

-    or approximately 6,300 dynamic clips (2 sec. color clip)

Digital storage of static images and dynamic clips:

-  JPEG lossy compression of dynamic clips with user
selectable compression level

  Retrospective and prospective clip capture during real time
imaging with a selectable duration of 1, 2, 3, or 4 seconds

  Editable clip capture from Cine replay

  Storage and retrieval of real time dynamic clips

  Storage and retrieval of frozen static images

  Storage and retrieval of reports

  Instant dial-in replay of dynamic clips or static images in
1-up screen format

  Perform Measurements and Calculations on current, as well
as on saved and retrieved images and clips

  Storage and retrieval of stress echo exam data (optional)

  Storage and retrieval of SieScape imaging panoramic images
(optional)

  Storage and retrieval of 3-Scape imaging 3D volume data, 3D
images and 3D animation clips (optional)

  Export of patient studies from Hard Drive to CD-RW Drive

  Exported images and clips in standard TIF and AVI file formats

  M-mode Still Frame Scroll and Store

  CW and PW Spectral Doppler Still Frame Scroll and Store

  Patient database sorting by Name, ID, Study Date and
Exam type

Stress Echo Imaging (Option)

(requires DIMAQ-IP and cardiac imaging options) The stress echo package provides tools for ECG-triggered acquisition, display, selection, comparison, evaluation and archiving of multiple cardiac loops during various stages of a stress echo examination. The software module is based on Microsoft Windows® 2000 standards.

Standard acquisition protocols for treadmill-ergometric-
and pharmacological stress with

-    2-Stage Exercise Stress Echo Protocol

-    3-Stage Exercise Stress Echo Protocol

-    6-Stage Pharmacological Stress Echo Protocol

 

  Full screen or ROI (region of interest) acquisition

  Easy workflow throughout the exam protocol

  Stage Timer

  Reference image display during acquisition

  Immediate review of acquired loops

  Flexibility to skip views or stages

  Flexibility to re-acquire and overwrite already acquired images

  Indication of current view, acquired views and skipped views
in the workflow diagram

  Wall Motion Scoring, 16-segment model with graphical
display and report printing

  LV Volume Measurements with report printing

  Ability for customized studies through Protocol Editor, with up

to 12 stages, 6 views per stage, 20 loops per view Digital storage and recall of stress echo exam data to the DIMAQ-IP integrated workstation and output to CD-R

SieScape Panoramic Imaging (Option)

(requires DIMAQ-IP option)

SieScape large field-of-view images are acquired with real-time high resolution gray scale imaging. These images present ultrasound information in anatomical context providing overall anatomical orientation for referring physicians, teaching and surgical consultation.

  Available on all curved and linear array imaging transducers

  Displays up to 60 cm in length or 180 degrees

  Unique cine display provides review capability of the
individual data frames composing the SieScape image

  Accurate measurements of enlarged organs and structures

3-Scape Real-Time 3D Imaging (Option)

(requires DIMAQ-IP option)

3-Scape imaging provides comprehensive, accurate and

fast 3D volume reconstruction from multi-frame objects.

The 3-Scape imaging package is fully integrated in the

system architecture and offers automated 3D volume

acquisition, which ensures geometrically accurate volume

reconstruction.

  Available on C6-3 3D curved array and Endo-V 3D mechanical
sector transducers

  Simultaneous display of real-time 2D image and continuously
updated 3D volume

  Flexible display formats of 3D rendered volume and MPR,
including quad screen display

  Comprehensive volume editing and post-processing tools

  Multiple views can be bookmarked for instant recall during
editing

  4 volume rendering modes: Surface, Max, X-ray and 3D
planes mode

DICOM 3.0 Connectivity (Option)

(requires DIMAQ-IP option)

Provides digital image transfer via a DICOM network for both printing and storage. The SONOLINE G50 ultrasound system acts as a DICOM Storage Class User and DICOM Print Class User and can be connected to a DICOM color or grayscale Printer and/or to DICOM workstation and archive devices.

DICOM Storage Class

  Allows connectivity to PACS

  Allows storage of all digital images and dynamic clips
(multi-frame objects) including patient demographic data

  Allows in Progress Store during the exam

DICOM Print Class

Allows connectivity and printing to DICOM print device

DICOM Modality Worklist (Option)

(requires DIMAQ-IP and DICOM 3.0 Connectivity options) Enables digital network connectivity to Hospital/Radiology/Cardiology Information Systems (HIS/RIS/CIS) via DICOM (HIS/RIS/CIS) network protocol gateway.

  Allows query and direct download from HIS/RIS/CIS system of
the patient work schedule to the SONOLINE G50 ultrasound
system.

  Automatically populates the New Patient form with patient
demographic information.

Cardiac Imaging Option

  Phased array imaging capabilities

  Steerable continuous wave Doppler (CW)

  Cardiac measurement, calculation and report package

  ECG module for ECG trace display and reference

Additional Array Port Option

  Allows the user to connect up to three (3) linear, curved array
and phased array* transducers simultaneously (*requires
cardiac imaging option)

  Compatible with all array transducers offered on the G50
system

  Can be added to the standard two array port configuration or
two array with sector port configuration

Sector Port Option

  Active sector port allows the user to connect and control
sector transducer types

  Compatible with sector transducers offered on the
G50 system

  Sector port can be added to the two array or three array port
configurations

DOCUMENATION DEVICES

Optional On-Board Video Devices

   Up to three documentation devices can be integrated and
controlled through the control panel

   Supported devices:

 

-    Mitsubishi P91W B&W Printer (standard equipped)

-    Sony SVO-9500 S-VHS VCR

-    Sony SVO-3500 VHS VCR

-    Mitsubishi CP-900 Color Printer

SYSTEM INPUT /OUTPUT

Video Standard

   PAL/CCIR: 625 lines, 50 Hz

   NTSC/EIA: 525 lines, 60 Hz

Video/Audio Input

   1 Composite color Video in, BNC-type

   1 Y/C Video in, S-terminal (SVHS)

   1 2-Channel Audio in (Right/Left), phone jack-type

Video/Audio Output

   1 Composite B/W Video out, BNC-type

   1 Composite color Video out, BNC-type

   2 RGB & Composite Sync out, mini D-SUB (15-pin)

   2 Y/C Video out, S-terminal (SVHS)

   1 2-Channel Audio (Right/Left), phone jack-type

Other Input / Output

   1 ECG lead connector, AIUM/NEMA standard

   1 ECG DC In connector, phone jack-type

   1 Foot switch connector, phone jack-type

  2 Remote control connector, mini jack (stereo)

System Connections

  Network

-   1 Ethernet connector, type RJ45 (10/1 00BaseT)

  Peripherals

-    2 Serial port RS232-C connector, D-SUB (9-pin)

-    1 USB port, Series A-type

SYSTEM DIMENSIONS

  System Height: 142.2 cm (56.0 inch)

  Width: 51.0 cm (20.1 inch)

  Depth: 79.8 cm (31.4 inch)

  Weight: 130 kg (286 pounds) without OEM's

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

back to ultrasoundpage